The three signal types (chapter 3)
Chapter 3 covers the fire alarm control panel (FACP) and the three signals it reports. It explains what initiates each signal. It also covers how a central station ranks and passes signals on, and how quickly a trouble signal must be looked into.
The same chapter discusses non-working devices that look like real ones, the operating instructions posted at the panel, and sub-systems tied into the base building system.
A useful way to practice is to read a described condition and decide which of the three signals it would produce. RankHigh's items take that form.
New York
Certificate of Fitness S-95 -- Supervision of Fire Alarm Systems (and Other Related Systems)
$79Your one-time purchase includes 90 days of access from the time payment clears. No subscription. No automatic renewal
- Prepared scope and limits shown clearly
- Targeted practice by weak area
- Worked answer explanations
- Missed-question and due-review queues
- 90 days of access
When an alarm comes in (chapter 4)
Chapter 4 walks through the holder's response to an alarm:
- Making the log entry
- Using the acknowledge, alarm-silence and system-reset functions, and their limits
- Why the panel will not reset while a device is still in alarm
- Restarting fans
- Not silencing or resetting before FDNY has verified the alarm
- A table linking each device to its activation, signal and restoration
- Building features the alarm triggers: smoke dampers, fire dampers, elevator recall and door release
Initiating and supervisory devices (chapters 6 and 8)
Chapter 6 covers the devices that start an alarm. These include smoke detectors (photoelectric, ionization and multi-sensor), heat detectors (rate-of-rise and fixed-temperature) and sprinkler waterflow devices. It also covers carbon monoxide detectors, single- and double-action manual stations with their protective covers, and flammable or combustible gas detectors.
Chapter 8 covers supervisory switches, such as valve tamper, pressure, water level, temperature, fire pump and emergency generator. It also covers bells, horns, speakers and strobes, the remote annunciator, and the difference between general and partial evacuation signals.
Unnecessary and unwarranted alarms
Section 6.8 explains when a building owner is liable for avoidable alarms. It sets a threshold of two within three months and a six-month liability window. It also covers the violation, correction and repeat-offense rules.
The section notes that malicious false alarms from manual boxes are not treated as unnecessary alarms. It also lists common causes of unwarranted alarms.
How RankHigh prepares these chapters
Our items describe devices and panel conditions in words and ask you to classify, sequence or apply a rule. We do not show device photos. FDNY does not publish whether the real exam does, so also study the booklet's own images.
Sources
- FDNY S-95 Notice of Exam and Study Material (Revised October 2026) · checked 2026-11-16
More on the FDNY S-95 Fire Alarm Supervision
- What is on the FDNY S-95 Certificate of Fitness exam?
- What does FDNY not publish about the S-95 exam?
- What score do I need to pass the S-95, and can I retake it the same day?
- How do I apply for and take the FDNY S-95 exam?
- Who needs an S-95, and is it the same as F-01, F-80, F-89 or S-78?
- What goes in the S-95 fire alarm log book?