FDNY S-95 Fire Alarm Supervision Exam Prep
Original practice for all 11 sections of the published exam outline, every question explained.
- Checked against Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit — official source · 2026-11-18
- Daily study plan
- Practice aimed at weak areas
- Missed-question review
Officially the Certificate of Fitness S-95 -- Supervision of Fire Alarm Systems (and Other Related Systems), set by Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit.
Try it free
Pick an answer and check it. Every question in full prep is explained this way.
An employee holds an F-80 certificate for the shelter where she works. The owner asks whether she must also obtain an S-95 for that same shelter. What is the correct answer?
Holders of the F-89, T-89, F-80 or F-53 are exempt from obtaining a separate S-95 for the same premises. Her F-80 for this shelter is therefore enough. The option saying she must pass the S-95 exam within her first year is wrong: no such deadline exists, because no S-95 is required at all. The option saying the F-80 covers the voice system but not the alarm panel is wrong because the exemption is not split by component. The option saying she must still file an S-95 application for the shelter's records is wrong because FDNY states no such filing duty for an exempt holder.
A building's subscriber names an employee to receive notifications from the central station about system status and to take action on them. What is this person's role called?
The designated representative is the person or entity the subscriber names to receive central station notifications and who is authorized to act on the protective signaling system. The impairment coordinator has a different role, which is safety precautions during an out-of-service condition.
A newly assigned S-95 holder takes over a building whose fire alarm panel is unfamiliar to them. Which step best matches what FDNY expects of the holder?
The S-95 holder must be familiar with how the panels at the location operate, which means getting the operations manual and panel instructions for the building. Depending on the central station, firefighters or the installer for panel knowledge leaves the holder unable to supervise the system.
Your sample result
You have not answered any of the sample questions yet.
Supervision of fire alarm systems: who needs an S-95, related Certificates of Fitness and permitted duties (chapters 1, 2, 7; Appendix A) · Definitions (section 1.1) · Components of the fire alarm system: the FACP, the three signal types and central-station handling (chapter 3)
Answer a sample question to see a worked explanation of how it is solved.
90 days of exam-specific preparation, worked explanations, realistic practice and a guided study experience. One payment. No subscription.
This is a short practice result from 3 questions — not a readiness estimate, a predicted examination score or an assessment of your chances.
Nothing you choose here is saved. Every RankHigh question is original, written from the formats Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit publishes.
The exam
What Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit publishes — and where it publishes nothing, we say so.
- Run by
- Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit
- Areas tested
- Supervision of fire alarm systems: who needs an S-95, related Certificates of Fitness and permitted duties (chapters 1, 2, 7; Appendix A), Definitions (section 1.1), Components of the fire alarm system: the FACP, the three signal types and central-station handling (chapter 3), In case of an alarm: log entry, acknowledge, silence, reset, device restoration and building features (chapter 4), Initiating devices and other related (supervisory) devices (chapters 6 and 8, first part), Prevention of unnecessary and unwarranted alarms (section 6.8), Tests, inspections and repair procedures; the alarm log book; central station; taking a system off-line (chapter 10, sections 10-10.6), Out-of-service situations and the impairment coordinator (section 10.7), Notification appliances, annunciators, evacuation signals and communication systems (sections 8.1-8.3, chapter 9), Fire extinguishers (chapter 11), Lithium-ion battery safety (chapter 12)
Source: Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit — official source ↗ · checked 2026-11-18
What you get
More than practice questions: each part of paid access feeds the next, so every session starts from what the last one showed.
Coverage
Prepared · All 11 prepared areas of the written exam
- Supervision of fire alarm systems: who needs an S-95, related Certificates of Fitness and permitted duties (chapters 1, 2, 7; Appendix A)Prepared
- Definitions (section 1.1)Prepared
- Components of the fire alarm system: the FACP, the three signal types and central-station handling (chapter 3)Prepared
- In case of an alarm: log entry, acknowledge, silence, reset, device restoration and building features (chapter 4)Prepared
- Initiating devices and other related (supervisory) devices (chapters 6 and 8, first part)Prepared
- Prevention of unnecessary and unwarranted alarms (section 6.8)Prepared
- Tests, inspections and repair procedures; the alarm log book; central station; taking a system off-line (chapter 10, sections 10-10.6)Prepared
- Out-of-service situations and the impairment coordinator (section 10.7)Prepared
- Notification appliances, annunciators, evacuation signals and communication systems (sections 8.1-8.3, chapter 9)Prepared
- Fire extinguishers (chapter 11)Prepared
- Lithium-ion battery safety (chapter 12)Prepared
Not covered
- Photograph- or diagram-based identification items — part of this hiring process that this product does not prepare.
- Exam-administration sample content — part of this hiring process that this product does not prepare.
- Alternative Issuance Procedure, application and fee mechanics — part of this hiring process that this product does not prepare.
Scoring, timing and retake rules are explained in What is on the FDNY S-95 Certificate of Fitness exam? and What does FDNY not publish about the S-95 exam?.
Questions
All 11 sections this administrator publishes: Supervision of fire alarm systems: who needs an S-95, related Certificates of Fitness and permitted duties (chapters 1, 2, 7; Appendix A); Definitions (section 1.1); Components of the fire alarm system: the FACP, the three signal types and central-station handling (chapter 3); In case of an alarm: log entry, acknowledge, silence, reset, device restoration and building features (chapter 4); Initiating devices and other related (supervisory) devices (chapters 6 and 8, first part); Prevention of unnecessary and unwarranted alarms (section 6.8); Tests, inspections and repair procedures; the alarm log book; central station; taking a system off-line (chapter 10, sections 10-10.6); Out-of-service situations and the impairment coordinator (section 10.7); Notification appliances, annunciators, evacuation signals and communication systems (sections 8.1-8.3, chapter 9); Fire extinguishers (chapter 11); Lithium-ion battery safety (chapter 12). Coverage is stated as a count of sections rather than a share of the examination.
The administrator does not publish a total item count, so none is stated here.
RankHigh is an independent preparation product. It is not affiliated with, endorsed by, or connected to Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit, the New York government, or any city, county or department. Application and hiring decisions are made by the hiring authority — check the official posting for anything that decides your application.