On this page
At a glance
- Extinguisher classes
- A, B, C, D and K
- Mounting
- Top no more than 5 ft high; bottom at least 4 in off the floor; never on the floor
- Rating example
- 3-A:40-B:C
- Inspections
- Monthly quick check; annual W-96 inspection
- Battery separation
- 2 ft at 20 kWh; 3 ft up to 50 kWh (by total capacity)
Using an extinguisher
The booklet treats extinguishers as tools for small, contained fires only. FDNY must still be notified every time one is used. It teaches the PASS method and gives mounting rules: the top no higher than 5 feet, the bottom at least 4 inches above the floor, and never resting on the floor.
New York
Certificate of Fitness S-60 -- Watchperson at Construction Sites (Citywide)
$79Your one-time purchase includes 90 days of access from the time payment clears. No subscription. No automatic renewal
- Prepared scope and limits shown clearly
- Targeted practice by weak area
- Worked answer explanations
- Missed-question and due-review queues
- 90 days of access
Classes, ratings and symbols
You need to know classes A, B, C, D and K, which agents suit each class, and what a multipurpose dry chemical unit is. The booklet shows how to read a rating such as 3-A:40-B:C.
It also describes the identification symbol for each class and what a slashed, shaded symbol signals. In the booklet these symbols appear as pictures. RankHigh practice describes them in words and never shows the images.
Inspections and tags
A watchperson should know about the monthly quick check and how it is recorded. They should also know about the annual inspection by a W-96 holder and the portable fire extinguisher (PFE) tag. The booklet explains how to spot a counterfeit tag by checking its hologram and QR code.
Lithium-ion battery safety
The booklet lists warning signs that mean you should stop and call 911. It gives lists of things to always do and never do, recommends only a partial charge, and says to use compatible chargers from the original manufacturer.
If a site has more than five devices, they belong in a dedicated, ventilated room with a self-closing door. The booklet sets separation distances by total battery capacity. It warns that extinguishers do not work on these fires and that a battery can reignite.
Pictures on the test
The booklet has many photographs, including alarm boxes, standpipe alarms, cylinders, heaters, extinguishers and PFE tags. FDNY's sample questions are text only, and FDNY does not say whether any real question includes an image.
RankHigh is not connected to FDNY. Its practice questions are text only and do not prepare picture-identification questions.
Sources
- FDNY S-60 Notice of Exam and Study Material (Revised March 2024) · checked 2026-11-18
More on the FDNY S-60 Construction Site Watchperson
- What is on the FDNY S-60 Watchperson at Construction Sites exam?
- What does FDNY not publish about the S-60 exam?
- What score do I need to pass the S-60 exam, and what if I fail?
- How do I apply for the S-60 exam, and do I need a security guard license first?
- How many S-60 watchpersons does a site need, and how is S-60 different from F-01?
- What does the FDNY S-60 study booklet cover, section by section?