Heating and Air Conditioning Maintainer preparation
Original practice for all 4 sections of the published exam outline, every question explained.
- Checked against MTA New York City Transit (Examinations Unit). The notice carries the 'New York City Transit' masthead, routes correspondence to 'Heating and Air Conditioning Maintainer, Exam No. 5620, MTA New York City Transit, 149 Pierrepont Street, Brooklyn, NY 11201, Attn: Exam Administration, 3rd Floor, Room 3.600', and states that 'The General Examination Regulations of the Department of Citywide Administrative Services apply to this examination, are part of this Notice of Examination'. DCAS supplies the regulations, not the test; DCAS does not publish this notice. — official source · 2026-11-22
- Daily study plan
- Practice aimed at weak areas
- Missed-question review
Officially the Heating and Air Conditioning Maintainer, set by MTA New York City Transit (Examinations Unit). The notice carries the 'New York City Transit' masthead, routes correspondence to 'Heating and Air Conditioning Maintainer, Exam No. 5620, MTA New York City Transit, 149 Pierrepont Street, Brooklyn, NY 11201, Attn: Exam Administration, 3rd Floor, Room 3.600', and states that 'The General Examination Regulations of the Department of Citywide Administrative Services apply to this examination, are part of this Notice of Examination'. DCAS supplies the regulations, not the test; DCAS does not publish this notice..
Try it free
Pick an answer and check it. Every question in full prep is explained this way.
A lock and tag are on a motor disconnect. Why should a meter still be used on the conductors before work begins?
A lock keeps the disconnect from being closed, but it does not prove the conductors are de-energized. A mislabeled disconnect or a second source could still feed them. Only a meter test confirms that no voltage is present. The claim that the meter actually stops the current is wrong because a meter only measures and cannot interrupt anything. The lock also does more than advise, since it physically holds the disconnect open. The rule that the tag cannot be signed until a reading is written on it is invented, because lockout tags have no such requirement. The idea that a meter reading drains the circuit is wrong because a meter draws almost no current. It cannot remove a live supply or make conductors safe to handle.
A split air-conditioning system has lost part of its refrigerant charge through a slow leak. Which pair of readings is typical?
With less refrigerant, the evaporator is starved, so suction pressure falls and the vapor picks up extra superheat. Low subcooling, not high, goes with a short charge, and high head pressure with high subcooling is the pattern of an overcharge.
How should the probe of an electronic leak detector be moved along a refrigerant line to check a joint?
Refrigerant vapor is heavier than air and sinks, so the probe is moved slowly just below the joint, where leaking gas collects. Moving the probe quickly past the joint from about a foot away means the sensor never gets enough gas to detect a small leak. Holding it in one place on top of the joint until the alarm sounds rests on the false idea that refrigerant rises. Gas that sinks does not reach a probe held above the joint. Pressing the probe hard against the joint to seal it from outside air is also wrong. The detector needs a flow of air to draw a sample, and pressing the tip onto the fitting can block the intake or soil the sensor.
Your sample result
You have not answered any of the sample questions yet.
Basic Electrical Theory · Electrical, Mechanical, Pneumatic and Hydraulic Devices · Tool Usage
Answer a sample question to see a worked explanation of how it is solved.
90 days of exam-specific preparation, worked explanations, realistic practice and a guided study experience. One payment. No subscription.
This is a short practice result from 3 questions — not a readiness estimate, a predicted examination score or an assessment of your chances.
Nothing you choose here is saved. Every RankHigh question is original, written from the formats MTA New York City Transit (Examinations Unit). The notice carries the 'New York City Transit' masthead, routes correspondence to 'Heating and Air Conditioning Maintainer, Exam No. 5620, MTA New York City Transit, 149 Pierrepont Street, Brooklyn, NY 11201, Attn: Exam Administration, 3rd Floor, Room 3.600', and states that 'The General Examination Regulations of the Department of Citywide Administrative Services apply to this examination, are part of this Notice of Examination'. DCAS supplies the regulations, not the test; DCAS does not publish this notice. publishes.
The exam
What MTA New York City Transit (Examinations Unit). The notice carries the 'New York City Transit' masthead, routes correspondence to 'Heating and Air Conditioning Maintainer, Exam No. 5620, MTA New York City Transit, 149 Pierrepont Street, Brooklyn, NY 11201, Attn: Exam Administration, 3rd Floor, Room 3.600', and states that 'The General Examination Regulations of the Department of Citywide Administrative Services apply to this examination, are part of this Notice of Examination'. DCAS supplies the regulations, not the test; DCAS does not publish this notice. publishes — and where it publishes nothing, we say so.
- Run by
- MTA New York City Transit (Examinations Unit). The notice carries the 'New York City Transit' masthead, routes correspondence to 'Heating and Air Conditioning Maintainer, Exam No. 5620, MTA New York City Transit, 149 Pierrepont Street, Brooklyn, NY 11201, Attn: Exam Administration, 3rd Floor, Room 3.600', and states that 'The General Examination Regulations of the Department of Citywide Administrative Services apply to this examination, are part of this Notice of Examination'. DCAS supplies the regulations, not the test; DCAS does not publish this notice.
- Areas tested
- Basic Electrical Theory, Electrical, Mechanical, Pneumatic and Hydraulic Devices, Tool Usage, Mathematical Calculations
What you get
More than practice questions: each part of paid access feeds the next, so every session starts from what the last one showed.
Coverage
Prepared · All 4 prepared areas of the written exam
- Basic Electrical TheoryPrepared
- Electrical, Mechanical, Pneumatic and Hydraulic DevicesPrepared
- Tool UsagePrepared
- Mathematical CalculationsPrepared
Not covered
- Competitive practical skills test — part of this hiring process that this product does not prepare.
- Schematics: 'Ability to read and interpret specifications and drawings' — part of this hiring process that this product does not prepare.
- 'Other related areas' beyond the five named areas — part of this hiring process that this product does not prepare.
Scoring, timing and retake rules are explained in What is on the MTA Heating and Air Conditioning Maintainer exam? and What does MTA leave out of the HVAC Maintainer exam notice?.
Questions
No. MTA's notice (No. 5620) says you take a qualifying multiple-choice test and a competitive practical skills test. You need at least 70% to pass the multiple-choice test, and only candidates who pass it are scheduled for the practical, which you must pass with at least 65%. Your score on the practical skills test decides your place on the eligible list. This product prepares the multiple-choice test, the step you must pass to reach the practical; it does not prepare the practical.
All 4 sections this administrator publishes: Basic Electrical Theory; Electrical, Mechanical, Pneumatic and Hydraulic Devices; Tool Usage; Mathematical Calculations. Coverage is stated as a count of sections rather than a share of the examination.
The administrator does not publish a total item count, so none is stated here.
RankHigh is an independent preparation product. It is not affiliated with, endorsed by, or connected to MTA New York City Transit (Examinations Unit). The notice carries the 'New York City Transit' masthead, routes correspondence to 'Heating and Air Conditioning Maintainer, Exam No. 5620, MTA New York City Transit, 149 Pierrepont Street, Brooklyn, NY 11201, Attn: Exam Administration, 3rd Floor, Room 3.600', and states that 'The General Examination Regulations of the Department of Citywide Administrative Services apply to this examination, are part of this Notice of Examination'. DCAS supplies the regulations, not the test; DCAS does not publish this notice., the New York government, or any city, county or department. Application and hiring decisions are made by the hiring authority — check the official posting for anything that decides your application.