FDNY S-13 Standpipe System Supervision Exam Prep
Original practice for all 15 sections of the published exam outline, every question explained.
- Checked against Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit — official source · 2026-11-21
- Daily study plan
- Practice aimed at weak areas
- Missed-question review
Officially the Certificate of Fitness S-13 -- Supervision of Standpipe System (Citywide), set by Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit.
Try it free
Pick an answer and check it. Every question in full prep is explained this way.
An impairment coordinator keeps the records of a building's standpipe inspections, tests and servicing. For what minimum period must ordinary records of this kind be kept on the premises or at another approved location?
The booklet requires the coordinator to keep records of inspections, tests, servicing and other maintenance for at least three years. Work witnessed by the Fire Department must be kept for five years. "Two years, since three years applies only to witnessed work" is wrong because three years is the general minimum for ordinary records. The longer witnessed period is five years, so two years falls short. "Five years, since each record counts as witnessed by the Fire Department" is wrong because only work the Fire Department actually witnessed carries the five-year period, not every record. "One year, after which they may go to storage if the owner agrees" is wrong because one year is below the three-year minimum, and the owner's agreement cannot shorten it.
Why must the impairment coordinator be made aware in advance of a planned removal of a standpipe system or its components from service?
The coordinator needs advance notice so that repair, servicing, alteration, testing or construction can be done without activating the system unnecessarily. The notice also lets the coordinator authorize and supervise the removal. Billing the owner "at quarter's end" is wrong because the coordinator's role is safety oversight, not invoicing. A Fire Department "fee for each system taken out of service" is wrong because the booklet ties advance notice to controlling the outage, not to collecting charges. A tenant "refund" is wrong because nothing in the procedure involves compensating occupants. Advance awareness exists to protect the building while the work is done.
A building's standpipe system has no Fire Department connection and is being taken out of service. Where is the out-of-service tag placed?
Without a Fire Department connection there is nowhere to hang a disc, so the system is tagged at its main control valve. The roof manifold, the tank gauge and a stairwell hose valve are not the booklet's tagging point.
Your sample result
You have not answered any of the sample questions yet.
Part 1 Introduction and Part 2 Responsibility of the Building Owner · Part 3 Out-of-Service Systems: planned removal, construction sites, unplanned conditions, fire watch, Fire Department notification and defect reporting · Part 3 Identifying OOS systems using discs/tags, tag requirement, systems fully or partially out of service, impaired equipment, tag levels, return to service
Answer a sample question to see a worked explanation of how it is solved.
90 days of exam-specific preparation, worked explanations, realistic practice and a guided study experience. One payment. No subscription.
This is a short practice result from 3 questions — not a readiness estimate, a predicted examination score or an assessment of your chances.
Nothing you choose here is saved. Every RankHigh question is original, written from the formats Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit publishes.
The exam
What Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit publishes — and where it publishes nothing, we say so.
- Run by
- Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit
- Areas tested
- Part 1 Introduction and Part 2 Responsibility of the Building Owner, Part 3 Out-of-Service Systems: planned removal, construction sites, unplanned conditions, fire watch, Fire Department notification and defect reporting, Part 3 Identifying OOS systems using discs/tags, tag requirement, systems fully or partially out of service, impaired equipment, tag levels, return to service, Part 4 General procedure for detail record keeping, impairments and safety, Part 5 Individuals authorized to perform tasks, and the 'May be performed by' columns of the Section 10.2-10.4 reference guides, Part 6 Definitions, Part 7 Different types of standpipe systems, Part 8.1-8.4 Roof manifold, Fire Department connection, alarms and supervisory devices, valves, Part 8.5 Fire hose including couplings and nozzles, Part 9 Water supply, Part 10.1 A complete summary of tasks of inspection, testing and maintenance, Part 10.5 Inspection, maintenance and testing notification activities and records, Part 11 Signage requirements and Part 12 NYC Building Local Law 58 of 2009, Part 13 Fire Department Code Section 905 and Rules 905-01, Part 15 Lithium-Ion Battery Safety
Source: Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit — official source ↗ · checked 2026-11-21
What you get
More than practice questions: each part of paid access feeds the next, so every session starts from what the last one showed.
Coverage
Prepared · All 15 prepared areas of the written exam
- Part 1 Introduction and Part 2 Responsibility of the Building OwnerPrepared
- Part 3 Out-of-Service Systems: planned removal, construction sites, unplanned conditions, fire watch, Fire Department notification and defect reportingPrepared
- Part 3 Identifying OOS systems using discs/tags, tag requirement, systems fully or partially out of service, impaired equipment, tag levels, return to servicePrepared
- Part 4 General procedure for detail record keeping, impairments and safetyPrepared
- Part 5 Individuals authorized to perform tasks, and the 'May be performed by' columns of the Section 10.2-10.4 reference guidesPrepared
- Part 6 DefinitionsPrepared
- Part 7 Different types of standpipe systemsPrepared
- Part 8.1-8.4 Roof manifold, Fire Department connection, alarms and supervisory devices, valvesPrepared
- Part 8.5 Fire hose including couplings and nozzlesPrepared
- Part 9 Water supplyPrepared
- Part 10.1 A complete summary of tasks of inspection, testing and maintenancePrepared
- Part 10.5 Inspection, maintenance and testing notification activities and recordsPrepared
- Part 11 Signage requirements and Part 12 NYC Building Local Law 58 of 2009Prepared
- Part 13 Fire Department Code Section 905 and Rules 905-01Prepared
- Part 15 Lithium-Ion Battery SafetyPrepared
Not covered
- Part 14 List of major changes in new S-13 — part of this hiring process that this product does not prepare.
- Code and NFPA content the booklet does not itself state — part of this hiring process that this product does not prepare.
- Photograph- or diagram-based identification items — part of this hiring process that this product does not prepare.
- Exam-administration sample content and application, fee, renewal and location mechanics — part of this hiring process that this product does not prepare.
Scoring, timing and retake rules are explained in What is on the FDNY S-13 Standpipe System supervision exam? and What does FDNY not publish about the S-13 exam?.
Questions
All 15 sections this administrator publishes: Part 1 Introduction and Part 2 Responsibility of the Building Owner; Part 3 Out-of-Service Systems: planned removal, construction sites, unplanned conditions, fire watch, Fire Department notification and defect reporting; Part 3 Identifying OOS systems using discs/tags, tag requirement, systems fully or partially out of service, impaired equipment, tag levels, return to service; Part 4 General procedure for detail record keeping, impairments and safety; Part 5 Individuals authorized to perform tasks, and the 'May be performed by' columns of the Section 10.2-10.4 reference guides; Part 6 Definitions; Part 7 Different types of standpipe systems; Part 8.1-8.4 Roof manifold, Fire Department connection, alarms and supervisory devices, valves; Part 8.5 Fire hose including couplings and nozzles; Part 9 Water supply; Part 10.1 A complete summary of tasks of inspection, testing and maintenance; Part 10.5 Inspection, maintenance and testing notification activities and records; Part 11 Signage requirements and Part 12 NYC Building Local Law 58 of 2009; Part 13 Fire Department Code Section 905 and Rules 905-01; Part 15 Lithium-Ion Battery Safety. Coverage is stated as a count of sections rather than a share of the examination.
The administrator does not publish a total item count, so none is stated here.
RankHigh is an independent preparation product. It is not affiliated with, endorsed by, or connected to Fire Department of the City of New York (FDNY), Bureau of Fire Prevention -- Public Certification Unit, the New York government, or any city, county or department. Application and hiring decisions are made by the hiring authority — check the official posting for anything that decides your application.